Power Systems Engineering
An electrical distribution system that functions optimally is essential for a reliable power supply. Every new load, expansion, upgrade and configuration change in your network can produce conditions for which your network was not originally designed. If there are faults in the protection system, any relatively small errors such as overloads, short circuits or earth faults can lead to significant financial damage as a result of uncontrolled interruptions to the voltage in your company. The network studies conducted by RENEWABLE show where critical points occur in your network. We provide you with information so that the right decisions can be made when planning upgrades or expansions of your electrical system. This results in lower operational costs, greater availability and minimum risk of faults. At this field of engineering, RENEWABLE provides the following services:
Load Flow Analysis
- Power flow analysis / Voltage drop study / Power factor correction
- Device evaluation / Transformer sizing
- Real & reactive power losses
- Bus voltages, currents, losses & power factors calculations
- 1&3 phase panel systems according to ANSI, IEC or NEC
Short Cirvuit Analysis According to ANSI / IEEE
- Maximum & minimum short circuit fault currents determination
- Calculate ½ cycle, 1.5 – 4, & 30 cycle faults (3-phase, L-G, L-L, L-L-G)
- Single-phase & panel systems device duty evaluation
Short Circuit Analysis According to IEC 60909 & 61363
- Short circuit study calculations based on IEC 60909
- Transient short circuit calculations based on IEC 61363
- Unbalanced L-G, L-L, & L-L-G fault current analysis
- 1-pole / 2-pole short circuit device duty for single-phase panel
Ground Grid Systems
- Ground grid study according to IEEE
- Ground grid study based on FEM
Cable Systems
- Cable capacity study according to IEEE 399 / NEC / ICEA P-54-440 / IEC 60502 / IEC 60364
- Protective conductor (PE) sizing based on IEC 60364
- Electric shock calculations based on IEC 60364
- Cable sizing study according to multiple criteria as load current, voltage drop, motor minimum starting voltage, short circuit, current & protective device requirements
- Cable Management & Cable Lists
Protective Devises
- PROTECTIVE DEVICE COORDINATION STUDY (Over current protective device coordination & selectivity / Equipment damage curve plotting – TCC)
- SEQUENCE-OF-OPERATION FAULT ANALYSIS (Device operation sequence graphical visualization / Detailed relay actions / Sequence of events / Normalized time current characteristic curves / Phase & Ground faults (symmetrical & asymmetrical)
Renewable Energy
RENEWABLE provides integrated services to clients seeking an innovative approach to developing and managing renewable energy projects and assets.
Our capabilities include Wind / Solar (photovoltaic and solar thermal) / Hydro / Combined Heat & Power (CHP) / Geothermal / Biomass & Biogas systems. Our services include:
- Policy advice & business strategy
- Options & risk assessments
- Site identification & selection
- Concept design & feasibility studies
- Concept design & feasibility studies
- Grid connection studies
- Detailed engineering design
- Project & construction management